An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of a refinery. A mixture of a hydrogen and hydrocarbon mixture was accidentally released into the firebox of a…

A tube in a hydrorefiner heater ruptured resulting in an extensive fire inside and outside the furnace. The main fire in the furnace was extinguished within 15 minutes and the escaping gas / vapour…
The accident occurred in a plant producing synthesised active ingredients for the pharmaceutical industry. An explosion and a fire occurred in one of the workshops of the plant. The chemical reaction…
A rupture of a tube in the furnace of an oil refinery caused it to loose 700 pounds of diesel and hydrogen resulting in a fire. The fire burned for a half hour with 30- to 40-foot (10 to 12 m) flames…
The accident originated in the isomerisation unit and propagated to the benzene saturation unit. The accident source was a mechanical rupture of one of the two compressors used to transfer hydrogen…
This incident occurred at a reactor for the isomerization of wax in a lube oil plant. The high-pressure reactor ruptured during a catalyst activation operation. A hot (400 C) gaseous stream of…
A 24" pipe carrying synthesis gas (Hydrogen = 43. 5%, Nitrogen = 14. 08%, Methane = 0. 2%, Carbon Dioxide = 12. 3%, Water = 29. 3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…
A fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat exchangers…
The event occurred in an alkylation reactor. Due to the rupture of a pipe (probably due to material failure), a power failure took place and the plant was automatically put in hot-stand-by mode. This…
The accident happened in a refinery unit, constructed ten years before. A pigtail ruptured in a steam reformer for the production of hydrogen, and caused a major fire, which destroyed most of the…
The accident took place in a tank-type pressurised separator on the synthesis gas line of an ammonia production plant. The pressurised separator operates at nominal values of 25 bar and 5°C. It…
In a fertiliser plant, an ammonia synthesis unit stopped following the malfunction of an alternator due to a thunderstorm. The safety features were operating normally, yet the synthesis gas (N2 / H2)…
The accident occurred on the hopper fine powders from a pair of cyclones (the hopper is the bottom conical part of the cyclone collecting the powder/dust separated from gas phase). A bursting disc…
A fire broke out at a flange inside a heat exchanger of the catalytic reforming unit of a refinery. This heat exchanger had the purpose to pre-heat the load of heavy oil and hydrogen by recovering…
A fire occurred at the desulphurisation unit of a refinery during maintenance work. On the day of the incident, a distillation unit was shutdown for a steam air tightness test. A leak was found at…
The fire occurred on the tube plate gaskets of 3 of the 4 exchangers loaded with catalytic reforming effluent. The fuel (500°C and p=30 bar) was a mixture of 30% hydrocarbons and 70% hydrogen. After…
Release of gas from a coking plant on a gas holder which ignited causing a fire. The accident took place during repair works. The gas was made of 65 % of hydrogen , 25 % of methane , 4. 1 % of carbon…
The incident occurred at a refinery unit for the desulphurisation of a light heavy oil. This unit was equipped with three hydrogen compressors. Two of them were usually operated and the third was…

This incident occurred at a refinery, on a pipe transporting hydrogen at 24 bar placed at 6 m above ground. A 15 cm long hydrogen flame was detected at an anti-leak system temporarily installed on…

A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.…