Skip to main content

HIAD Nature Event - Release Type: Mixed


Coke oven gas was released from a pipeline during maintenance works. The pipeline was supplying the burners of the coke oven with coke oven gas. The original reason for the so-called gas-stop was…

A major vapour cloud explosion (VCE) occurred at a gas storage tank (a gasometer) of a coking unit. Several days before the incident, several gas detection alarms had frequently sounded. Also, the…

The event occurred at a hydrogen processing unit of the refinery. A mixture of hydrocarbon and hydrogen leaked ad the 90-debrees-elbow of a carbon steel pipe. The mixture formed a cloud which…
Explosion within a blast furnace occurred at the plant manufacturing iron. The event occurred at one of the blast furnace of the plant, which exploded. The explosion was so powerful that the entire…
In a polyethylene manufacturing plant, the explosion of a flammable cloud (isobutene, ethylene, hexane and hydrogen) escaped from a reactor during maintenance caused 23 fatalities and 314 injured…
A gas release occurred in the building containing the compressors for the recirculation of process gas of a plant producing fertilisers. The process gas was a mixture of hydrogen and nitrogen. It…
During the polymerization of ethylene in a 750 litres pressurized reactor, an exothermic runaway decomposition occurred and ethylene and its decomposition products were released through the two…
Workers were performing demolition on a disused furnace. While removing a 10 inch valve from a pipe used to supply coke gas fuel to the furnace, flammable liquid was unexpectedly released and ignited…

Explosion as a result of detonation of gases inside container in turbine section causing 2 casualties .

An explosion occurred around noon while conducting hot work (with a disc saw) on a 320-m³ fixed-roof tank at a pharmaceutical plant employing 240 personnel. The tank belongs to a waste treatment unit…
The explosion occurred in the ammonia/hydrogen separator of the ammonia reactor due to metallurgical problem.
A release of a mixture of hydrogen, nitrogen and ammonia ignited and exploded in the ammonia synthesis unit. The release was due to a cracked pipe and occurred at the level a flange situated at the…
The event took place in the on one out of the seven reactors for ammonia synthesis. The day of the accident, preparation works for the decennial pneumatic test (previous pneumatic test was carried…
A mechanical failure occurred in a gasification reactor, which caused a violent (abrupt, sudden) depressurisation of the reactor. The consequences were the projection of tiles of the refractory…

[Note of HIAD event validator: The event description relates to a real accident, the details of which however are not publicly available. The descriptors are based on the analysis provided by the…

Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
An explosion occurred in an electrostatic precipitator whilst it was being accessed for maintenance. The explosion caused an inspection hatch cover, which had been unbolted, to be blown off and…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…
The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…