Skip to main content

Explosion in an ammonia plant (211)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in an ammonia plant

The event took place in the on one out of the seven reactors for ammonia synthesis. The day of the accident, preparation works for the decennial pneumatic test (previous pneumatic test was carried out in 1978) were started on that unit. The reactor was put out of service and a slow pressurisation with process gases (hydrogen and nitrogen) was carried out at ambient temperature. It was necessary to carry out many pneumatic cycles of pressurisation and depressurisation because of leaks from some flanges. After any cycle, the bolts of the flanges were tightened and a purging with nitrogen at 8 bar was carried out. Eventually, a slow pressurisation with process gases was in progress at ambient temperature when the explosion occurred, 20 minutes after the start, at an internal pressure of 250 bar. The explosion caused one fatality and one injury, destroyed the upper part of the column; metallic parts of the reactor were thrown in a radius of many metres around it. It also caused the complete destruction of the building where the reactor was located.
Event Date
June 9, 1988
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The original investigation report is not available. According to the eMARS report (see reference), some experts suggested the possibility that accident occurred due to an internal explosion (deflagration) in the reactor. The ROOT CAUSE could be tentatively attributed to an inadequate testing procedure (too long period between testing, use of flammable gas for testing, failure to correctly identify hazards and mitigate risks)
Facility Information
Application Type
Application
Ammonia production
Specific Application Supply Chain Stage
Components Involved
Ammonia synthesis reactor
Storage/Process Medium
Actual Pressure
25
Design Pressure
0
Location Type
Location description
DESCRIPTION OF THE REACTOR It had a volumetric capacity of 8,000 litres, was 7. 7 metres high and had a diameter of 850 mm, with a design pressure of 300 bar.
Operational Condition
Pre-event Summary
The steel reactor had been manufactured in 1929 and since then It had been regularly tested.
Consequences
Number of Injured Persons
3
Number of Fatalities
1
Currency
Property Loss (onsite)

10000000

Property Loss (offsite)

0

Post-event Summary

The material damages were estimated at approximately 20000 millions of lire (approximately 10 million of euros). eMARS reports 1 fatality and 3 injuries, ARIA 1 resp. 1, Rigas&Amyotte reports 2 resp. 3, and 15,000 evacuated persons.

Event Nature
Emergency Action
After the accident, on-site arrived the local fire brigade and the police. The ammonia production was interrupted. The ammonia production was interrupted and the whole factory was stopped by the authorities to establish the causes of the explosion. On June 14 the production in the other plants not involved in the explosion started again.
Release Type
Release Substance
H2, N2
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description in the European database eMARS https://emars. jrc. ec. europa. eu/en/emars/accident/view/d2b442eb-a58a-f251-5a69-667a0f3a3e1d (accessed September 2020)

Page of the newspaper La Stampa of the 11 Juneavailable at the La Stampa archive: http://www. archiviolastampa. it/component/option,com_lastampa/task,search/mod,libera/action,viewer/Itemid,3/page,3/articleid,0960_01_1988_0123_0041_13018749/ (accessed September 2020)

Rigas F. , Amyotte P. , Hydrogen safety, Green chemistry and chemical engineering, CRC Press, Taylor & Frances Group; 2012. ISBN-13: 978-1439862315

Event no. 49 of the French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/49/ (accessed November 2025)