The leak occurred on the inlet pipe (P=21 bar, T=320°C) of the diesel desulphurization reactor of a refinery. Hydrogen and diesel fuel were released in the gas phase. The hydrocarbons contaminates…
A release occurred following the rupture of a pipe of 250 mm in diameter. 350 kg were released to the atmosphere in 11 minutes, consisting in 80% of hydrogen, 5% of hydrogen sulphide (H2S) and 4% of…
Leakage of a mixture of hydrogen, nitrogen, citric acid, hydrofluoric acid and hydrogen sulphide occurs during ventilation shutdown on high temperature PVC furnaces. The accident follows an…
In an ammonia production unit, a 350-bar leakage of synthesis gas (ammonia + hydrogen) occurred in the compressor room. The leak was the result of the failure of a weld on a line (2") at the outlet…
The incident occurred in the hydrogenation reactor and products cooling unit. The reactor operated under vacuum conditions and the cooling medium was water. Toxic, flammable and explosive substances…
A petroleum refinery experienced a catastrophic rupture of a heat exchanger in the catalytic reformer / naphtha hydrotreater unit. The heat exchanger catastrophically ruptured because of High…
In a plant producing calcium carbide (CaO + 3C -> CaC2 + CO), a dust collector clogged, probably due to the failure of the cleaning device (nitrogen nozzles) which allowed the dust to build a plug…

A small fire occurred at the vent stack of an ammonia processing unit in a plant producing fertilisers and other nitrogen-based chemicals. A safety shutdown procedure of the ammonia processing…

A university lab was investigating the production of hydrogen and methane from biomass made of wooden chips or sawdust. The experimental furnace was a concrete cylindrical furnace of the diameter of…
There was a small leak of syngas (a mixture mainly consisting of hydrogen and carbon monoxide) resulting in a localised fire at a bolted flange joint on the outlet carbon steel pipework of the High…
The event occurred while re-starting the ammonia production unit after a technical stop, a synthesis gas (50% hydrogen, 17% ammonia, methane and nitrogen) leak ignited on a flange located just after…
The release of a blast furnace gas occurred at a section of pipework, due to the rupture of valve seal. The gas did not ignite and the fire service attended as a precaution. The gas was both…
In the collective treatment plant of a chemical platform, the truck tank of 25 m³ containing hydrochloric acid (HCl) rose in pressure at 11 am; leakage of acid solution and gas evolution occurred in…