Release of toxic and flammable mixture from a hydrogenation reactor
The incident occurred in the hydrogenation reactor and products cooling unit. The reactor operated under vacuum conditions and the cooling medium was water. Toxic, flammable and explosive substances (flammable gases, hydrogen sulphide and hydrogen) escaped to the open air from a bend in the water cooler. The heat-exchanger of the cooling unit was corroded by the action of the hydrogen sulphide contained in the reaction products. The hydrogen sulphide emission caused bad odour in the surroundings of the plant area. The population was alerted.
Event Date
March 8, 1991
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the corrosion of the material by hydrogen sulphide.