Skip to main content

HIAD Nature Event - Release Type: Mixed


A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…
The release occurred on a pipeline inside a steam cracking unit located between two hydrogenation units. The gaseous mixture transported through this line (2" diameter, 30 bar, 40°C) was composed of…
The leak occurred at an heat exchanger of the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A…
In a fertilizer manufacturing plant, a gas leak occurred at an ammonia unit heat exchanger located in a ventilated area outside. The operator partially stopped the unit, set up steam hoses and…
The incident involves a gas booster provided by a manufacturer. This device is used in the experimental platform of the project to raise the pressure in pipelines from 60 to 80 barg (from 6 to 8 MPa)…
The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…
A mixture of mainly carbon monoxide and hydrogen was released from a pipeline transferring process gases in a not further specified unit of a chemical plant, generating a flammable mixture which…
An explosion occurred in the transformation section of a fertiliser manufacturer, resulting in 8 deaths and 3 injuries. A leak in the secondary pipeline of the 1st conversion system, and caused the…

This near-miss occurred at a company producing compressed gas bottles according to customers requests. When preparing a gas mixture containing oxygen and nitrogen, by mistake hydrogen was added,…

A hydrogen explosion ruptured and fragmented a 6-inch steam condensate pipe elbow at of a nuclear plant. The component affected was a steam piping of a heat exchanger used for removing residual heat…
The utility production facilities (electricity, water, air, and steam) at a refinery were isolated from the power grid and switched to two turbine generators in anticipation of a storm. However, at 9…
The vessel affected by the incident was a gas storage used for the hydro-desulphurisation process. The desulphurisation gas had high hydrogen content. The vessels had cracks in the upper transverse…
In a chemical plant , a process gas leak (4% ammonia and 88% hydrogen) occurs during a purge operation. The cloud of gas ignites and explodes. An employee is killed.
While de-plugging a cooling circuit, a blockage suddenly released, causing a heavy movement of a flexible hose connected to the system. The flexible hose hit several small pipes and one employee…
A leak occurred on a line connecting the hot separator to the cold separator of a refinery diesel desulphurization. The alert was given by the activation of the fixed H2S detector. The 30 bar…
A joint failure allowed a mixture of hydrogen and nitrogen into the atmosphere. Failure of double cone joint on waste heat boiler in synthesis loop caused release of synthesis gas at 28. 7 MPa and…
A hydrogen leak alarm was received in the control room from the reformer of the hydrogen plant of a chemicals manufacturing facility. The reformed was depressurised and the leak stopped. The leak was…
During the start-up operation (phase) of a cryogenic unit, a separator exploded, releasing ethane, ethylene, methane and hydrogen. The bursting of a tank was caused by a 1600 mm long incipient crack…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A release of contents of a pressure vessel occurred when a longitudinal weld tore open. The vessel had been shut down and had just been put into use again when the incident occurred. The gas mixture…