unintended hydrogen formation from a truck with chemical tank
In the collective treatment plant of a chemical platform, the truck tank of 25 m³ containing hydrochloric acid (HCl) rose in pressure at 11 am; leakage of acid solution and gas evolution occurred in the upper part of the tank. The emergency plan of the site was triggered. The rescue confined 5 employees and switched off the electrical power on the site. The police interrupted the traffic. Reliefs opened the manhole of the tank to reduce the internal pressure. At 6pm, they measure 124, 923 and 230 ppm of HCl around the 3 manholes and a hydrogen (H2) level below the LEL. Staff containment was lifted. A specialized company emptied the tank until 9:30pm. According to the IC inspection, the incident was due to an incompatibility between HCl and the material constituting the tank (INOX), the acid attack leading to the formation of H2.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
an incompatibility between HCl and the material constituting the tank (INOX), the acid attack leading to the formation of H2.