Skip to main content

HIAD Specific Application Supply Chain Stage: Unintended Hydrogen Production - Chemical Reaction


This event occurred at a theatre building. A contractor was conducting routine maintenance on a dry pipe sprinkler system in the basement of the theatre. By opening the pipe, an explosion occurred…
An explosion occurred on a ship loaded with a cargo of 2333 tonnes of unprocessed incinerator bottom ash. Flammable gas generated by the ash produced two explosions: the first one was in the…
Hydrogen leak due to a fault with non-process related battery equipment. After reporting the hydrogen leak, fire crews have been called to a gas terminal. The leak was due to a fault with non-process…
The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150…

A vessel exploded at a plant producing pharmaceutical products. At the time of the incident, the plant was producing a substance called Dekon 139. The Dekon had already been synthesised, and…

The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The reaction was ongoing when one of the tank started overflowing with foam. The…

At a water sports center, a 35-liter container of caustic soda (NaOH) spilled down an aluminum metal staircase leading to a technical room housing other chemicals and electrical cabinets. Hydrogen…

A release of hydrogen and steam occurred in the battery room of a nuclear power plant around 21 h. Site agents neutralised the batteries. Noting the failure of the smoke extractor, public…

The event occurred at the factory producing multilayer circuit boards by a multistep dip operation. An employee inadvertently mixed 55 gal of 50 percent hydrogen peroxide into 110 gal of 30 percent…

The incident occurred at a pulp mill plant producing fluting media. The explosion took place at a pulp storage tank and was caused by the combustion of a hydrogen-ammonia gas mixture. The roof of…

The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper part of the electrostatic…
The bolts on a not further specified industrial facility failed after approximately 4000 hours in service (approximately 18 months in service). Their failure bolts causedH2S leaks. The bolts…
A tank received, after a negative reactivity test with the bottom supernatant of the tank, 20 m³ of methyl hydro-dichloro-silane, then 24 m³ of a mixture of oil and tar (negative reactivity test) and…
An employee was preparing a batch of glycol stearate emulsifier in a vessel. Upon completion of product, the quality control lab reported that the pH was too high and the product needed to be…
The incident occurred in a pharmaceutical plant. A disc ruptured on the vent of a reactor and the reaction mixture was projected onto a frontage of the synthesis workshop. It caused a spill of 700 l…
Damage of shipping containers of a ship, due to the reaction of phosphor pentoxide with wine, which lead to the production of phosphoric acid and hydrogen. The overpressure was successfully…
This near miss occurred at metal smelting unit of a foundry. At 9:45 a. m. , due to a power outage, the cooling pumps of two furnaces containing nickel and chromium stopped. One of the two furnaces…
A vapour explosion, followed by a fire, occurred at a drier in a plant making titanium sponge. When titanium containing water was put into the drier, it came to contact with the edge of the…

The incident occurred at a storage tank of an organic chemical plant. The storage tank was containing cyclo-dodecane (C12H24, melting point: 60 °C), and a tank trucks was being filled at the…