Bolts rupture due to hydrogen embrittlement
The bolts on a not further specified industrial facility failed after approximately 4000 hours in service (approximately 18 months in service). Their failure bolts causedH2S leaks. The bolts fractured as a result of a hydrogen embrittlement mechanism (Hydrogen Stress Cracking) in a H2S rich atmosphere and in presence of humidity.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The cause was a material/component failure due to hydrogen embrittlement (Sulphide Stress Cracking). The steel used for the bold belonged to a martensitic steel family which is not advised for use for continuous operation with wet H2S. The ROOT CAUSE could be attributed to a design failure.