Accidental hydrogen production and fire in a electrical products plant
Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150 kg containers, producing hydrogen (7. 5 kg per container). The heat of reaction ignited the gas. The fire was extinguished with sand.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The ARIA report (see references) identifies as possible root cause the fact that the calcium containers were the probably insufficiently sealed to deal with the abnormal quantity of water cumulated.