Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150…

The incident occurred at a pulp mill plant producing fluting media. The explosion took place at a pulp storage tank and was caused by the combustion of a hydrogen-ammonia gas mixture. The roof of…

A small hydrogen cylinder was beeing filled at a facility for high-pressure testing. The cylinder had a nominal working pressure of 2000 psi (approximately 140 bar) and the filling a target…

A tube trailer-tractor was traveling on a highway, left the road into the median, striking a guardrail and then overturning. As a consequence, a tube valve cracked at the stem resulting in a slow…

A gaseous tube trailer gone off road in a countryside area and landed on one side. All cylinders were loaded to a pressure of 200 bars. The impact with the ground has caused the rupture of a high…

An explosion occurred at a the compressed gas storage facility of a research laboratory, during filling hydrogen cylinders from a hydrogen tube trailer. Workers used a manifold containing residual…

[Note of HIAD Validator: this is a preliminary event description, he CSB investigation is still ongoing] An explosion occurred on an isolation valve on the piping providing coke oven gas to a coke…

A CGH2 trailer lost control and left the road travelling for approximately 65 feet before rolling approximately one quarter times. After which it impacted a fence and a utility pole and came to…

On a highway, a truck loaded with 400 gas cylinders crashed at night for an undetermined cause against a concrete wall and overturned. It slipped 150 m, before several 200 litre cylinders of hydrogen…
Discharge pressure of a hydrogen compressor on a chloride plant fell to alarm level without any prior warning and simultaneously three bumps were heard. Smoke was seen coming from the hot motor…

[Note HIAD validator: this an incident where a hydrogen system was affected, as effect of the initiating event, overpressure of LH2 tank with helium, but it is not a LH2 incident]. The second…

A stainless steel manifold ruptured during experimental operation. The manifold was made of stainless steel and had a diameter of three inch (7. 5 cm). The hardware was off-the-shelf, slightly…

The explosion occurred while restarting the ammonia reactor. Synthetic gas (70% H2) was released at the flange of the relief valve of the turbo-compressor. The explosion was followed by a jet fire.…

This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…

The incident occurred at a chemical laboratory of a university. Six students were conducting experiments on producing nitrification carriers for waste leaching when an explosion followed by a fire…

The incident occurred at the hydro-dealkylation (HDA) plant of an aromatics manufacturer. The affected component was a heat exchanger part of the hydrogen purification system. This part failed…
An explosion and fire occurred at around at a company specialised in hydrogen storage in slid materials. The accident occurred while a press used to compact magnesium hydride and natural graphite…
The accident occurred in the organo-metallic compound production unit, on a transport container for aluminium alkyls, which exploded during a cleansing process at the washing station. The incident…
The event occurred at an ethylene production plant. The plant was shutdown at the time as the supply of compressed air to the gauges had inadvertently been switched off. This failure of the air…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…