The burst disc activated prematurely on a small hydrogen tube trailer. The pressure at which the activation occurred was between 80 and 100 bar (1200 and 1500 psig). The design activation pressure…
The release occurred during refuelling of the mobile storage system. This operation was part of a series of tests aiming at verifying the tightness of the system. When opening a valve to connect…
An explosion occurred at a hydrogen boiler of a chemical manufacturing plant producing hydrogen gas and other substances. A potential flow restriction in the feed line to a hydrogen-fired boiler…
A leak occurred at a dispenser hose of a hydrogen refuelling station. On the day of the accident six FCVs had already been filled. Four minutes after the start of the filling of a seventh vehicle,…
During a transfer of liquid hydrogen from a commercial tanker to a stationary receiving vessel, a leak developed in the bayonet fitting at trailer-vessel connection. The leak produced a hydrogen…
The accident occurred during the filling of hydrogen into a fuel cell vehicle (FCV) at a hydrogen station. The gas detector in the dispenser detected a leak, and the equipment was shut down. A…
The accident occurred at a mobile hydrogen station during a fuelling test for a fuel cell vehicle. The day before, the gas detector in the dispenser detected a leak and the equipment was shut down…
The leak occurred on the compressor of a hydrogen testing laboratory. The location of the leak in the cylinder cap of one of the ultra-high-pressure hydrogen compressor unit. The hydrogen gas…
This incident occurred on a high-pressure hydrogen compressor part of the hydrogen production and storage unit of a testing laboratory. While in operation, a hydrogen gas detector installed above…
A leak occurred at the compression unit of the refuelling station. The employees had just initiated the normal procedure of starting up the hydrogen production equipment, and opened the three shut…
A leak occurred while refuelling a fuel cell vehicle with hydrogen at a mobile hydrogen refuelling station. The hydrogen gas leak detection alarm (at 1% LEL) on top of the dispenser body went off,…
The drivers of a CGH2 tube trailer-tractor was travelling to a delivery. they stopped to perform a visual walk-around inspection of the vehicle and discovered an audible leak coming from the neck…
A hydrogen leak occurred on a hydrogen and fuel cells bus when in service. The bus driver received a low hydrogen level alarm [Note of HIAD validator: the nature of the alarm is not further…
At a hydrogen production facility, hydrogen stored in a 40 MPa hydrogen storage unit leaked from the main body of a fitting of the storage pressure and flow control system. The leak was not…
In 1990 the Space Shuttle fleet was grounded for several months by an elusive hydrogen leak occurring during the procedure of fuelling of the liquid hydrogen tank of a space shuttle. The Columbia…
A liquid hydrogen leak occurred at the aerospace company (high Tier Seveso). The facility is specialised in production and handling of cryogenic propellants for engines of space vehicles. A 53 m³…
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.