leakage of potassium hydroxide from a water electrolyser
The incident occurred at an alkaline electrolyser in a renewable hydrogen production plant. It consisted of an explosion which brough to the release of potassium hydroxide solution (KOH) from the electrolyser stacks. An abrupt leak at the stack lead to a short circuit and the release of alkaline at 30 bar and 70°C. This release caused the smokescreen of the production room. The equipment shut down and automatically went into safety mode in accordance with the integrated safety system. No employees were in the electrolyser room and outside no impacts were detected.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was the damaging of a electrolyser membrane and the explosive combination of oxygen and hydrogen. The investigation revealed the following: (1) The assembly of the cells to stack caused mechanical deformation at the micro lines took place. (2) This induced to flow restriction: because of the deposits coming from the activation of the electrodes, it came to a blockade of alkaline lines. (3) This resulted in local high temperatures, which destroyed the membrane. (4) The mixture of hydrogen and oxygen with the presence of electricity leaded to the explosion (5) The frame of the stack was damaged and alkaline was released to the electrolyser room. In absence of further information of the reasons for the mishap during assembly, the ROOT CAUSES could be identified in shortcomings of the electrolyser design and of installation procedures.