Skip to main content

Leak on a CGH2 trailer (1141)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Leak on a CGH2 trailer

The drivers of a CGH2 tube trailer-tractor was travelling to a delivery. they stopped to perform a visual walk-around inspection of the vehicle and discovered an audible leak coming from the neck threads of a tube. They notified the company, which dispatched a local emergency response team. The team proceeded to vent the hydrogen in the leaking tube. The trailer was returned to the shipping location to disable the defective tube valve.

Event Date
July 1, 2013
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was probably the loosening of a threaded connection of a valve, probably due to road travel vibrations. The ROOT CAUSE is not provided, however, an effective design should be able to take into account road vibrations on a road vehicle.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

Threaded Connection

Storage/Process Medium
Storage/Process Quantity
305
Location Type
Location description

DESCRIPTION OF THE UNIT The trailer consisted of ten tubes, with a capacity of 12000 gas cubic feet each (ca. 30. 5 kg). This is also the value provided by PHMSA for the released amount. However, the report states also a 'amount in package' of only 77. 8 gas ft3, which would indicate an empty tube. This is unclear and conrotatory.

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Lessons Learned

The preventing/mitigating measures worked well: (i) the regular inspection by drivers along the route, and (ii) the emergency handling by depressurising the leaking tube and releasing its content to the atmosphere. The loosening of threaded connection due to road vibration is a common glitch. It is however unclear, in this and similar events, how this could be avoided. Is the root cause related shortcoming when installing / maintaining the connections, or to unexpected road conditions during travel?

Event Nature
Emergency Action

The company proceeded to vent the hydrogen of the leaking tube locally. Then the trailer was returned to the shipping location to disable the defective tube valve.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2013080039 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)