Implosion/explosion on a furnace copper metallurgy company
A hydrogen explosion occurred on a furnace in a company of copper metallurgy. The incident occurred at the end of the production cycle, when the furnace bell is lifted at the end of the cooling process. The operator in charge of the lifting was thrown away and slightly burned in the face. The victim was evacuated and the emergency services were alerted. The building structures (windows, doors, roof) experienced serious damage. The power supply was switched off. The firefighters arrived after 30 minutes, secured the area, inspected the buildings and took measurements of the natural gas concentration. Access to the workshop was blocked. [ARIA event 57436]
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
According to the experts, the explosion was caused by the presence of a small quantity of hydrogen in the bell. Nevertheless, the vacuum pump was functioning normally. During the simulation of the accident conditions, several technical problems appeared that could explain the presence of residual hydrogen at the time of the accident.