collision of a truck carrying Hydrogen cylinders

On a highway, a truck loaded with 400 gas cylinders crashed at night for an undetermined cause against a concrete wall and overturned. It slipped 150 m, before several 200 litre cylinders of hydrogen caught fire and set the truck on fire as well. The police stated that it was “a large fire with detonations”. The 400 gas cylinders were connected together and many of the cylinders had fallen out of their racks. In order to reduce the danger of further explosions, the fire-brigade cooled the gas cylinders with water for two hours. The highway remained closed for eight hours. The driver cabin burned completely. The damage was estimated at 200,000 Euros, not including the damage to the tarmac. The truck driver was taken to hospital with heavy injuries.
Event Date
April 30, 2005
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was a road crash. Nothing is reported on the state of health of the drivers, or on possible environmental factors which could have contributed to the crash. Therefore, in absence of details, the ROOT CAUSE can be attributed to a human error which brought to a loss of control of the vehicle. An important factor which probably contributed to escalation was that all the cyinders were all connected together.
Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved
gas cylinders
Storage/Process Medium
Storage/Process Quantity
15
Storage/Process Units
Actual Pressure
20
Design Pressure
20
Location Type
Operational Condition
Pre-event Summary
Assuming that all the 200 l cylinders were completely filled at 20 MPa, the truck was carrying a non-credible amount of hydrogen, possible only if it were in liquid form. From the picutre, the cylinders appear standard 50 l, 20 Mpa bottles, corresponding to 290 kg of H2.
Consequences
Number of Injured Persons
1
Number of Fatalities
0
Currency
Property Loss (onsite)

200000

Post-event Summary

The driver was brought to the hospital.

Lessons Learned
The source does not report any lesson learnt. The fact that the cylinders were all connected to each other made possible a release of the whole load at once. This is a scenario which should be avoided during transport. A corrective design measure could be the creation of subsystems, each provided with proper pressure control (e. g. shut-off valves to be closed during when travelling).
Event Nature
Emergency Action
The highway was closed to traffic for 8 hours. To reduce the risk of further explosions, the fire-brigade cooled the gas cylinders with water for two hours. Due to the absence of near water sources, a long water hose had to be connected to a source in the nearest town.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Die Welt news of 30 April 2005 https://www. welt. de/regionales/nrw/article842473/Gastransporter-explodiert. html (accessed Aug 2023)

PSI Database ENSAD https://www. psi. ch/en/ta/ensad (not online since 2024)