Skip to main content

Explosion and fire in chemicals production plant (234)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion and fire in chemicals production plant

The accident occurred in the organo-metallic compound production unit, on a transport container for aluminium alkyls, which exploded during a cleansing process at the washing station. The incident was caused by a pressure build-up inside the container caused by flammable gases, mainly hydrogen, formed by the chemical reaction of aqueous caustic soda solution with the aluminium alkyl residues. This cleansing of the transport containers is a standard procedure after return from customers and before a new filling. However, in this particular case, even after several attempts it was impossible to completely remove the deposits on the inner wall of the container. Tests aiming at the detection of reactive alkyl residues showed negative results. Thus, the deposits were exposed to an aqueous solution of caustic soda (NaOH). Since no production of heat or gases had been detected over a period of several hours, to increase the effectiveness of the cleaning procedure the container was sealed (against the instruction) and kept revolving around its longitudinal axis on a roller system. After a short time of this process, the container burst, torn apart along the longitudinal axis, while part of is bottom was blown away and damaged a heptane pipeline. The released heptane ignited, and the whole building caught fire. The container had been sealed infringing operating instructions. The substances involved were aluminium, aluminium alkyls, heptane (H₃C₅CH₃), sodium hydroxide (NaOH), hydrogen.
Event Date
September 24, 1998
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the pressure build-up inside the container by formation of flammable gases, mainly hydrogen. The container had been tested for reactive material, as prescribed by the procedure. However, the container had been sealed, against what prescribed by operating instructions. This could be the ROOT CAUSE, but it is impossible to determine if this was mainly a human error, or a lack of operative knowledge of the employees.
Facility Information
Application Type
Application
organo-metallic compound production
Specific Application Supply Chain Stage
Components Involved
chemicals transport container, heptane pipeline
Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary
The event occurred after various failed attempts to perform the cleaning process according to instruction.
Consequences
Number of Injured Persons
1
Number of Fatalities
1
Currency
Property Loss (onsite)

1800000

Post-event Summary

According to ARIA report, the injured persons were two. According to ZEMA , only 1. The material damage were assessed around 3,6 M de DM

Lessons Learned
This is an accident where hydrogen was produced accidentally, by reaction of chemical product; therefore, in general, measures aiming at avoiding recurrence of the same type of accidents should concentrate in preventing formation of explosive atmospheres.
Event Nature
Release Type
Release Substance
H2, C7H16
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
Flame Type
References
References

Event description in the European database eMARS https://emars. jrc. ec. europa. eu/en/eMARS/accident/view/61423583-fd94-5ba7-3791-09853ce40d9d (accessed December 2020)

Event description in the French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/19461/ (accessed December 2020)

Event from German database ZEMA https://www. infosis. uba. de/index. php/de/site/2854/zema/index/3065. html (accessed December 2024)