Skip to main content

HIAD Facility - Storage Medium: Other


This event occurred at a theatre building. A contractor was conducting routine maintenance on a dry pipe sprinkler system in the basement of the theatre. By opening the pipe, an explosion occurred…
An explosion occurred on a ship loaded with a cargo of 2333 tonnes of unprocessed incinerator bottom ash. Flammable gas generated by the ash produced two explosions: the first one was in the…
Hydrogen leak due to a fault with non-process related battery equipment. After reporting the hydrogen leak, fire crews have been called to a gas terminal. The leak was due to a fault with non-process…
The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150…

A vessel exploded at a plant producing pharmaceutical products. At the time of the incident, the plant was producing a substance called Dekon 139. The Dekon had already been synthesised, and…

The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The reaction was ongoing when one of the tank started overflowing with foam. The…

At a water sports center, a 35-liter container of caustic soda (NaOH) spilled down an aluminum metal staircase leading to a technical room housing other chemicals and electrical cabinets. Hydrogen…

A release of hydrogen and steam occurred in the battery room of a nuclear power plant around 21 h. Site agents neutralised the batteries. Noting the failure of the smoke extractor, public…

The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper part of the electrostatic…
A tank received, after a negative reactivity test with the bottom supernatant of the tank, 20 m³ of methyl hydro-dichloro-silane, then 24 m³ of a mixture of oil and tar (negative reactivity test) and…
Damage of shipping containers of a ship, due to the reaction of phosphor pentoxide with wine, which lead to the production of phosphoric acid and hydrogen. The overpressure was successfully…

The incident occurred at a storage tank of an organic chemical plant. The storage tank was containing cyclo-dodecane (C12H24, melting point: 60 °C), and a tank trucks was being filled at the…

The incident occurred at a chemical laboratory of a university. Six students were conducting experiments on producing nitrification carriers for waste leaching when an explosion followed by a fire…

The accident occurred in the organo-metallic compound production unit, on a transport container for aluminium alkyls, which exploded during a cleansing process at the washing station. The incident…
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system…
An explosion and fire occurred at a chemical plant applying silicone coatings. The blast occurred when some polymethyl hydrogen siloxane was accidentally fed into a reactor, together with the correct…
This incident occurred when subcontractor two workers were widening air vents on the roof of a building hosting a tank containing hydrogen chloride solution. This intervention was necessary to to…
An hydrogen explosion occurred within the off-gas system, causing the stop of the sump pump; subsequently both trains of the standby gas treatment system were declared inoperable. The sump is part of…