Explosion at a pipe in a nuclear power plant (522)
This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.
Explosion at a pipe in a nuclear power plant
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system did not have a safety function during operation. The explosion tore apart the pipe, with loss of radioactive steamThe 10 cm diameter pipe had totally disintegrated over a length of 2 to 3 meters. About 25 pieces of debris scattered around and 2 to 3 m of pipe was completely gone. The leak was stopped by closing an undamaged shutoff valve. An explosion detector was triggered during the accident and other monitoring devices briefly delivered readings at the scale limit. However, the nature of the event was not fully recognised by the operators, who isolated the leak and continued operations. The investigations suggested that the hydrogen (formed by radiolysis of the water) accumulated in a part of the pipe between catalytic recombiners. The explosion was close to a valve connected to the reactor pressure vessel, but the valve was closed at the time and was not affected. A subsequent investigation of all German BWRs indicated that the design had a unique vulnerability to this type of event.
The INITIATING CAUSE was the formation of an explosive hydrogen-oxygen mixture in a section of a pipe. The cause of the explosion was the formation of an explosive hydrogen-oxygen mixture, produced by radiolysis in all boiling water reactors during regular operation. The risk that the gas could collect in the pipe leading from the reactor lid and explode was overlooked in the safety assessments. The ROOT CAUSE was the lack of knowledge of the phenomenon and its related hazards. When designing and operating a system containing water steam, it was assumed that no non-condensable gases (hydrogen, oxygen, nitrogen, etc. ) could exist in its pipes. The fact that the operators considering the event a non-safety-related failure and continued the operation without reporting, while the formal investigation found it a case requiring operative actions and reporting, indicates a misunderstanding or non-clarity of the legal procedures.
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.
Contact info
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.