Skip to main content

HIAD Specific Application Supply Chain Stage: Unintended Hydrogen Production - Radiolysis


The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system…
A hydrogen explosion caused burns contaminated with radioactive dust to a member of the plant's maintenance crew. Three other workers escaped injury. The accident occurred in the basement of the…
An in-tank explosion occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and ignited due to air…
Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72. 210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…
On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…
A hydrogen explosion ruptured and fragmented a 6-inch steam condensate pipe elbow at of a nuclear plant. The component affected was a steam piping of a heat exchanger used for removing residual heat…
A hydrogen leak was discovered inside an auxiliary building of a nuclear power plant recently licensed. The plant had never reached criticality and was in cold shutdown at the time of the event. The…