Explosion at off-gas recombiner of a nuclear power plant
A hydrogen explosion caused burns contaminated with radioactive dust to a member of the plant's maintenance crew. Three other workers escaped injury. The accident occurred in the basement of the plant’s turbine building during work on an out-of-service recombiner (an equipment for the recombination of hydrogen and oxygen produced by radiolysis). The post-incident investigation found that a leak in a valve on the system allowed the hydrogen gas to build up in the pipe where the employee was working with a grinding wheel.
Event Date
January 18, 1992
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING cause was the leak in a valve of the recombiner, which allowed for hydrogen build-up in a pipe section where worked were grinding. Nothing is reproted on the root cause, but a tentative ROOT CAUSE can be attibuted to lack of measures aiming at detecting presence of hydrogen before workers start grinding works.