Accidental formation of flammable gas from chemical waste on a ship
An explosion occurred on a ship loaded with a cargo of 2333 tonnes of unprocessed incinerator bottom ash. Flammable gas generated by the ash produced two explosions: the first one was in the forecastle store and the second in the cargo hold. They caused extensive damage to ship structures and injuring a crew member. Laboratory tests carried out during the investigation have established that hydrogen gas was the only flammable gas released by the load on board. The presence of 2. 6% non-ferrous metals including aluminium, the alkalinity of the cargo, and an increased moisture content due to heavy rain during loading led to the generation of hydrogen. Enough hydrogen could have been released to form an explosive atmosphere.
Event Date
January 13, 2017
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was the accidental production of hydrogen from the reaction between ash and moisture, assisted by heavy rain. The ignition source for the hydrogen air mixture was most likely to have been electrical arcing between the contactors in the switch gear in the emergency free pump starter panel when the chief engineer stopped the pump. The ROOT CAUSE was related to “inappropriate and inadequate” testing protocols in place for assessing if the waste could produce flammable gases were. Moreover, the no autorisation for ashes transportation had been asked to the authorities.