HIAD Nature Event - Ignition Source: Electricity


An explosion occurred on a ship loaded with a cargo of 2333 tonnes of unprocessed incinerator bottom ash. Flammable gas generated by the ash produced two explosions: the first one was in the…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…
This incident occurred at a chlorine production plant. A number of minor explosions occurred in the interrupter pot on a chlorine cell of the electrolyser. No injuries or damage were reported. No…
An explosion occurred at a aerospace testing centre, while testing a liquid hydrogen turbo-pump, part of a rocket engine. On the day of the incident, seven seconds after the rotation speed of the…
This incident occurred at a company producing building elements. The process implies the production of a small quantity of hydrogen, which is usually dispersed into the environment without…
An employee used a small industrial vacuum cleaner on an unnamed process. During this process, hydrogen gas built up from a reaction between sulphuric acid and aluminium swarf. When the vacuum…
The laboratory works with soil bacteria that cannot survive in the presence of oxygen. As a result, research work is conducted inside a plastic chamber in which the chemical constituents in the air…
A gas release occurred in the building containing the compressors for the recirculation of process gas of a plant producing fertilisers. The process gas was a mixture of hydrogen and nitrogen. It…
A wash machine was being used to clean aluminium trays with burnt on product. The auto wash in normal situations cleaned steel trays, and not aluminium. The cleaning fluid contained sodium hydroxide…
In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…

A fuel cells and hydrogen city bus was refuelling at a hydrogen refilling station. It had just terminated this operation and the engine was restarted, that an explosion occurred at the back of the…

Electric spark ignited hydrogen in a captive advertising balloon.

The incident occurred at a facility performing material tensile tests in hydrogen at cryogenic temperatures. At the end of the test, the cryostat top was removed. In order to increase vaporization…

The boat was a 6. 5 m semi-rigid electric-powered inflatable canoe, mainly used for greeting and directing pleasure boaters in harbour. It exploded without a flame shortly when an employee of the…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
It was a small incident in a heat-electric power plant. The alarm was registered at 11:26 and the fire was extinguished at 12:03. The incident took place during tests using the reserve power…

One turbine was stopped for minor repairs and adjustment. The generator’s excitation breaker and air-operated disconnect breakers were opened. When the turbine generator had nearly completed its…

The explosion occurred at a hydrogen drier used for the treatment of the hydrogen used as coolant in a power generator. The hydrogen leaked, entered the contactor panel box of the drier and was…

This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…