Explosion on a hydrogen compressor of a silane manufacturer (1170)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion on a hydrogen compressor of a silane manufacturer

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to surrounding piping and equipment. The consequence was the release of Trichlorosilanes (TCS). This compound converts to hydrochloric acid (HCl) when released into the atmosphere. It was estimated that approximately 1,784 pounds of HCL were released during the event (5000 pounds is the maximum legally allowed). Two employees were light injured as a result of firefighting activities. The compressor had been revamped by installing a new 24-inch head piston with a 24-inch piston. The new piston failed during operation. The detailed series of events: 7 September, 3:47 PM equipment failure in the compressor room of the hydrogen recovery building. The piston in one of the cylinder failed and allowed hydrogen gas to enter an adjoining variable frequency drive room. The control room operator stopped the process and halted the flow of process gasses to the compressor. 7 September, 4:00 PM the hydrogen gas that had entered the variable frequency drive room was ignited by an electrical component, resulting in an explosion and subsequent fire. The company firefighter teams were deployed. 8 September, 4:00 AM, emergency response activities were completed.

Event Date
September 7, 2017
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was the mechanical failure of the piston of one of the hydrogen compressor cylinders. The administration in charge concluded that the incident was due to a “sudden and unavoidable failure of process equipment” and classified it as malfunction. In this case, the ROOT CAUSE would be the same as the immediate cause. However, the fact that the new piston failed after only 127 days of operation suggests that something went wrong during the manufacturing or design phase

Facility Information
Application Type
Application
Silicon production
Specific Application Supply Chain Stage
Components Involved

piston, cylinder,compressor

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

The compressor had been modified few months before the incident, by replacing a piston of the compressor cylinders. The new piston had a diameter of 615 mm allowing to increase throughput in respect to the old 525 mm piston. The new piston failed after only 127 days of operation.

Consequences
Number of Injured Persons
15
Number of Fatalities
0
Post-event Summary

The sources are not agreeng on the number of affected people. Some report only 2 light injuries among firefighters, other speak of 13 people with light respiratory difficulties due to HCl. The amount of hydrogen released is unknown. Almost 800 kg of HCl were released, as consequence of the hydrogen explosion.

Event Nature
Emergency Action

After the development of explosion followed by a fire, the company deployed 3 brigades consisting of 30 firefighters. They conducted also on-site and off-site mobile air quality monitoring during the event, measuring hydrochloric acid (HCL), trichlorosilanes (TCS) and Carbon Dioxide (CO). Roadways in close proximity to the plant were closed during the incident and a shelter in place was implemented for the residents in close proximity to the plant.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

BERNREUTER news of MArch 10, 2018 https://www. bernreuter. com/newsroom/polysilicon-news/article/faulty-piston-caused-explosion-at-wackers-u-s-polysilicon-plant/ (Accessed April 2025)

Final report on the legal investigation issued by the Tennessee Department of Environment and Conservation (TDEC) (not available any more online)