Skip to main content

Explosion from accidental hydrogen production (332)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion from accidental hydrogen production

This incident occurred at a company producing building elements. The process implies the production of a small quantity of hydrogen, which is usually dispersed into the environment without consequences. A plant operator was preparing the mix of substances to produce the material for making the blocks, by blending the various components in a mixing chamber. (1) During a break in production the operator took the opportunity to wash out the mixer in accordance with his work instructions. He did this by manually emptying out the water hopper into the pre-weigh batcher. However, he neglected to refill the water and when he switched the controls back to automatic, the programme software did not highlight that the water container was empty (as the water hopper had been emptied manually, the digital readout still read ‘full’). The water is and ingredient of the mix but also keeps the mixture cool. (2) During the subsequent mixing batch, the operator noticed an “excessive mix time” alarm on the mixer panel. This alarm ceases the process and dumps the mixer contents. However, the operator noticed an inconsistency in the mixed material discharge, which was a sludge rather than a fluid concrete. He interpreted this as a blockage and followed the written procedure for dealing with this by taking manual control and introducing as much water as possible to thin and cool the mix by opening the water hopper valves. During this, a second alarm went off reading “mix temperature invalid”, indicating that the mix temperature was not falling within the recognised range of 0 - 99 °C. (3) The IP went up to the mixer platform to investigate the reasons for the alarms and mix inconsistency. He lifted the mixer inspection hatch. He took an inspection lamp (later revealed to be faulty), the nearest one to hand, to illuminate the interior of the mixer. This caused an explosion which injured the operator, despite he was wearing the correct personal protection equipment (PPE).
Event Date
August 7, 2007
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INTIATING CAUSE was the accidental production of hydrogen because insufficient water was added to the batch. This resulted in a rapid temperature increase which induced a higher production of hydrogen than the normal negligible quantity. The lower water quantity was a mishap of the operator, who manually emptied the mixer and neglected to refill the water; when he switched the controls back to automatic, and the programme software did not highlight that the water container was empty. Despite the presence of functioning local exhaust ventilation I the mixer, , the hydrogen gas was ignited when the hatch was opened. The most likely IGNITION SOURCE was the faulty lamp - all other lighting in the vicinity was safety, explosion-proof lighting. This could have been related to a human mistake. However, the post-incident investigation concluded that the “operator was acting in accordance with his training and instruction and the company's written safe system of work”. Therefore, the ROOT CAUSE lies predominantly in shortcoming of the operative procedure and of the equipment design, particularly the automation part.
Facility Information
Application Type
Application
Construction company
Specific Application Supply Chain Stage
Components Involved
Building block mixer
Storage/Process Medium
Storage/Process Quantity
0
Actual Pressure
0
Design Pressure
0
Location Type
Location description
DESCRIPTION OF THE PROCESS The company produce building blocks called autoclaved aerated concrete (AAC). It is also sometimes referred to as aerated concrete building blocks or insulating building blocks. (1) Sand and water are first mixed to form a slurry. (2) Anhydrite, lime, cement and PFA powders are then dispensed into the mix. (3) Glycol-coated aluminium powder is added in the form of a slurry which has been mixed elsewhere and maintained in a hopper and kept cool. The aluminium is added in the last few seconds before the mix is dropped into the car. All powders are pre-weighed and dosed automatically via a computer-controlled system. The mix was then discharged into a car, from which moulds are filled. Aluminium and water produce a small amount of hydrogen gas which usually disperses from the car into the surrounding ventilated area and out through roof vents.
Operational Condition
Consequences
Number of Injured Persons
1
Number of Fatalities
0
Post-event Summary

The explosion resulted in temporary injuries including loss of sight, burns and cuts.

Event Nature
Emergency Action
The operator was wearing safety glasses and a hard hat, which were blown off by the blast.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description provided by HSE, original source confidential

Also uptaken by H2TOOLS https://h2tools. org/lessons/hydrogen-explosion-concrete-block-production-plant (accessed December 2025)