Explosion at a chlorine electrolyser
This incident occurred at a chlorine production plant. A number of minor explosions occurred in the interrupter pot on a chlorine cell of the electrolyser. No injuries or damage were reported. No previous explosion had occurred, and this was considered an indication that hydrogen concentration within the pot was normally below flammable limits. The ignition was believed to have resulted from the detachment of the dispersing tray in the pot, the resultant lack of a controlled break in the conductive sodium hydroxide stream leading to the release of sufficient electrical energy to ignite the flammable gas mixture. However, it was also thought that other conditions could provide sufficient energy to ignite hydrogen and air mixtures, and that elimination of the possibility of electrical ignition would be very difficult.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING CAUSE was the formation of an explosive mixture containing hydrogen in the electrolyser cell, with successive ignition and explosion. The source did not identify the underlying reasons for the presence of hydrogen more than the lower flammability limit. Nevertheless, the return of experience revealed the absence of diagnostics able to provide information on the status of the parameters process and to identify deviation from the normal operative conditions. In this sense, at least one component of the ROOT CAUSE is the lack of proper safety design.