Skip to main content

Explosion in a trays cleaning unit (312)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in a trays cleaning unit

A wash machine was being used to clean aluminium trays with burnt on product. The auto wash in normal situations cleaned steel trays, and not aluminium. The cleaning fluid contained sodium hydroxide (NaOH). When it entered in contact with the cleaning fluid a "froth" formed in the wash tub, accompanied with hydrogen gas. A cleaning worker was requested to clean up the froth, and used a wet vacuum cleaner. This cleaner seemingly also removed the hydrogen element with the froth, which in turn ignited due to sparking from the vacuum cleaner motor.
Event Date
July 15, 1999
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was the accidental formation of hydrogen when washing aluminium tray with sodium hydroxide. There was a lack of understanding of the cleaning product used and its applications, as COSHH sheets on this product, available on site, explicitly stated that this product was not to be used on aluminium. The ROOT CAUSE is failure to understand and apply procedures.

Facility Information
Application Type
Application
Industrial cleaner
Specific Application Supply Chain Stage
Components Involved
Industrial vacuum cleaner
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
1
Number of Fatalities
0
Post-event Summary

The cleaner was uninjured but took time off due to shock, which resulted in the incident being reported.

Lessons Learned
This incident is an example of a low-technology industrial process where things went wrong when something was changed to the process. The process had been designed for washing used for steel parts. When washing aluminium parts, the cleaning fluid behaved differently. In absence of an extensive knowledge of the ongoing chemical process, operators try usually to remediate to the unexpected results with what is available onsite. However, to avoid the incident would hace been enough to read the safety sheets held by the company, which specifically stated not to use on Aluminium. There waas a lack of understanding and availability of this information on behalf of manager. Nevertheless, the investigation conclusions were that
Event Nature
Emergency Action
No emergency action was stated in the report
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description provided by HSE, original source confidential