Skip to main content

Explosion at a rocket centre (629)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion at a rocket centre

An explosion occurred at a aerospace testing centre, while testing a liquid hydrogen turbo-pump, part of a rocket engine. On the day of the incident, seven seconds after the rotation speed of the pump had reached its steady state (45,000 rpm), excessive vibration was detected. The pump was stopped but a loud bang was heard. The operator started to inject nitrogen gas. One and a half minutes after the bang, flames were seen in front of the testing building, coming from burning cables. An investigation revealed that the cam of the turbo pump damaged, causing hydrogen gas to leak out. Hydrogen gas discharged from the vent stack on a liquid hydrogen tank also caught fire. [Note of HIAD validator: this report was orignally provided by the database RISCAD, now uanvailable. It is now in the KHK database (see references). Details are unclear, probablydue to the machine translation from Japanes. For example, it is unclear what a 'cam' is in this case, and the escalation to the LH2 tank was reproted only by RISCAD, not by KHK].
Event Date
November 17, 1987
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was the damaging of the LH2 pump. ROOT CAUSE is unknown.

Facility Information
Application Type
Application
Aerospace
Specific Application Supply Chain Stage
Components Involved
water pump, rocket engine, liquid hydrogen tank
Location Type
Operational Condition
Pre-event Summary

A test was ongoing

Consequences
Number of Injured Persons
1
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/incident_db. html (accessed May 2025)

The first entry in HIAD was coming from RISCAD, which is now closed.