HIAD Facility - Storage Medium: Other


Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…

At a rocket engine testing facility, a combustion experiment of the pre-burner (gas generator for driving the turbopump) was being conducted, before testing the turbopump. The pre-burner is the…

The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…

Hydrogen enrichment of the gaseous phase in a rail tanker initiated an exothermic reaction between hydrogen and chlorine which in turn triggered fire of iron chloride.

The incident occurred during maintenance works at a hydro-cracking unit of a refinery (the report does not explicitly mention the unit, but it is plausible to assume that it was a hydro-cracking…

A deflagration occurred at a chemical plant during a synthesis operation involving sodium tri-acetoxy-borohydride inside a 5,300-litre reactor. Around 5:30 pm, the technician observed that the acetic…
The fire, 1 m high fire occurred in a pipe at the inlet of the hydrodesulphurisation unit of a refinery. The fire was caused by the leak of the pipe content, hydrogen and diesel fuel. According to…
A fire broke out on a transformer transforming 225,000 V into 15,000 V in a metallurgical plant. This transformer supplies electrical power the site and to a neighbouring factory. In the following…
the hazmat crews evacuated the workers at the Atmel building and established a safe zone. The crews used liquid nitrogen. The biggest danger was the possibility of an explosion.
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72. 210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…

A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up…

The event occurred in the continuous casting of hot metallic melt of the plant. Cooling water leaked through a crack in the cooling water inlet pipe of a secondary cooling line and directly into the…
The explosion occurred while maintenance personnel were grinding a high-pressure injection (HPI) pipe, which had been recently cut at approximately 18 inches from the nozzle connecting the HPI pipe…
In a chemical plant (SEVESO), corrosion on the water side of a cooling exchanger caused water to enter the sulphuric acid and attack the steel in the tank. This reaction produced hydrogen that…
The fire broke out in the acid etching tank of the ferric chloride manufacturing unit of a SEVESO-classified chemical plant. In this tank, the attack reaction of the iron metal with hydrochloric acid…
On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…

NOTE: one of the source of this event attribute the explosion to the recombination of oxygen and hydrogen formed by thermolysis. However, the classic reaction products in the case of molten metal…

[NOTE of HIAD Validator: the attribution to hydrogen formation as cause of the explosion is 'probable 'but not fully demonstrated]. Two explosions in two different sprinkler systems occurred, wit the…
The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…

[NOTE of the EVENT VALIDATOR: this is a natural gas event, related to the NG supply chain. It may be however of interest for hydrogen-NG mixture transportation in pipeline. ] A 30-inch natural gas…