Skip to main content

Hydrogen accidentally produced by electropolishing (289)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Hydrogen accidentally produced by electropolishing

A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up within the vessel of a hydrogen - oxygen mixture generated during the process. The vessel was laid horizontally with the only unsealed opening being a man-way in the front end face. There were no measures aiming at evacuating the gasses generated within vessel, and/or at avoiding sources of ignition. Significant quantities of hydrogen likely to be generated given attempt to electropolishing vessel in two halves with consequential large cathode / anode area and energy input. The vessel was approximately half full of concentrated (sulphuric / phosphoric) acid. The explosion resulted in injuries, a fatality and in the ejection of a substantial quantities of the acid.

Event Date
October 11, 2000
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING cause was the accidental production of a hydrogen-oxygen mixture while electroplating. A CONTRIBUTING CAUSE was that this was the first such job undertaken by those injured, inexperience and failure to identify risk played a role The ROOT CAUSE is management shortcoming. Industrial standard were available but not applied. The workers had not knowledge of the hazards involved and there was no mitigating/preventive measure.

Facility Information
Application Type
Application
Steel manufacturing
Specific Application Supply Chain Stage
Components Involved

Pressure vessel for chemical storage

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

Maintenance works (electropolishing) were ongoing.

Consequences
Number of Injured Persons
1
Number of Fatalities
1
Post-event Summary

The explosion resulted in one injured and one fatality and in the ejection of a substantial quantities of the acid.

Investigation Comments

The following comments were recorded by the inspector: Industry standard for treatment of such vessels appears to be to:1) Electro-polish end caps prior to assembly and then to electro-polish internal circumference with the vessel continually rotated on powered rollers and with a cathode hung from centres into a small volume of electrolyte in the base of the vessel2) Evacuate generated gases by feeding air into vessel and / or providing extraction. Vessel involved in accident was first such job undertaken by those injured - inexperience and failure to identify risk are considered to be the main underlying causes.

Lessons Learned

It was the first time that the workers executed the process which brought to the incident. Inexperience and failure to identify risk are considered to be the main underlying causes. There were standard practice in place. The industry standard for treatment of such vessels appears to be to: 1) electropolishing end caps prior to assembly and then to electropolishing internal circumference with the vessel continually rotated on powered rollers and with a cathode hung from centres into a small volume of electrolyte in the base of the vessel 2) evacuate generated gases by feeding air into vessel and / or providing extraction. None of these steps were undertaken and no preventing measure was put in place.

Event Nature
Emergency Action

No attempt to avoid sources of ignition or to evacuate gasses generated within vessel. The vessel was laid horizontally with the only unsealed opening being a man way in the front end face.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event description provided by HSE, original source confidential