Hydrogen explosion in a foundry.
The event occurred in the continuous casting of hot metallic melt of the plant. Cooling water leaked through a crack in the cooling water inlet pipe of a secondary cooling line and directly into the hot melt (temperature > 1500 °C). This resulted in the formation of hydrogen which ignited on the hot surface. The pipe in question had been in operation for a prolonged period. The material analyses of the component showed that the rupture occurred as a consequence of fatigue. The annual visual inspection had revealed no signs of imminent failure.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING cause was the leaking of cooling water onto the melted metal, which produced hydrogen by thermolysis, followed by its ignition. The root cause was probably a design or inspection deficit, because the cooling pipe failed due ageing due to fatigue.