An explosion in a sulphonation plant.
The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper part of the electrostatic filtration plant (electrostatic precipitators). The most serious effects of the pressure wave were the violent detachment of the manhole cover of the plant, rupture of two insulating supports and deformation of the gas distributor plate. [DECHEMA incident database, event no. 05/ 2001]
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
Moisture-bearing and corrosive gases entered the electrostatic filtration plant (ESP) during the start-up phase and during operation of the plant. Air from an air dryer is used for cleaning, to prevent deposition of corrosive and conductive moisture on the thermo-protective insulation of the upper part of the filtration plant and lines. The cause of the explosion is probably the presence of hydrogen generated in the converter, in the inlet moisture separator and/or in the acid scrubber (absorber) by the reaction of iron with sulphuric acid. The ignition source of the hydrogen / air mixture were electrical discharges observed in the ESP. This suggests a design shortcoming.