collision of a CGH2 trailer
A CGH2 trailer lost control and left the road travelling for approximately 65 feet before rolling approximately one quarter times. After which it impacted a fence and a utility pole and came to rest on the roadside. Local fire and police were dispatched and secured the scene and maintained initial isolation distance according to the emergency response guidebook. Also the emergency response team of the company arrived on and checked the condition of the trailer, looking for leaks. They identified "bubbler" type neck leaks on two tubes. “Bubbler” indicates that lead detection fluid bubbled continuously but not rapidly (approximately 1 cc/10 sec). The leaks continued for approximately 3 hours. An hydrogen detector was placed above the leaks to determine atmospheric hazards due to the flammability of hydrogen. The detector never exceeded 7% of the low flammability limit (LEL). The emergency teams decided to transfer the contents of the two leaking tubes to an empty hydrogen tube trailer. Once complete, the company team checked the tubes for leaks again and found none. The LEL in the atmosphere had dropped to 0% of LEL. The tractor and trailer was up-righted by a crane and towed back to the company home terminal.

INITIATING CAUSE was a traffic accident. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).