Skip to main content

collision of a CGH2 trailer (1144)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

collision of a CGH2 trailer

A CGH2 trailer lost control and left the road travelling for approximately 65 feet before rolling approximately one quarter times. After which it impacted a fence and a utility pole and came to rest on the roadside. Local fire and police were dispatched and secured the scene and maintained initial isolation distance according to the emergency response guidebook. Also the emergency response team of the company arrived on and checked the condition of the trailer, looking for leaks. They identified "bubbler" type neck leaks on two tubes. “Bubbler” indicates that lead detection fluid bubbled continuously but not rapidly (approximately 1 cc/10 sec). The leaks continued for approximately 3 hours. An hydrogen detector was placed above the leaks to determine atmospheric hazards due to the flammability of hydrogen. The detector never exceeded 7% of the low flammability limit (LEL). The emergency teams decided to transfer the contents of the two leaking tubes to an empty hydrogen tube trailer. Once complete, the company team checked the tubes for leaks again and found none. The LEL in the atmosphere had dropped to 0% of LEL. The tractor and trailer was up-righted by a crane and towed back to the company home terminal.

Event Date
December 29, 2014
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

INITIATING CAUSE was a traffic accident. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

CH2 tube neck

Storage/Process Medium
Location Type
Location description

DESCRIPTION OF THE UNIT The trailer consisted of 10 tubes. The PHMSA source provides a amount of released hydrogen of 10 GCF, which results in a negligible quantity of few tens of grams. The capacity is not provided, but it could be assumed that it ranges from 300 to 400 kg.

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

69020

Property Loss (offsite)

0

Lessons Learned

This is a case of a small leak, by which the leaking hydrogen cannot form a flammable mixture in air. For this reason, the emergency team could proceed to the transfer of the hydrogen from the leaking tubes to another trailer. In the case of greater leaks, the better strategy would be to let the hydrogen venting, keeping at safe distance the emergency teams

Event Nature
Emergency Action

The emergency team worked to identify the location and the intensity of the leak(s), using the soap method and a hydrogen LEL detector. After which, they proceeded to transfer the hydrogen in the leaking tubes to a second, empty trailer.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident E-2015010130 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)