Skip to main content

CGH2 trailer collision (1136)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

CGH2 trailer collision

A tube trailer-tractor was traveling on a highway, left the road into the median, striking a guardrail and then overturning. As a consequence, a tube valve cracked at the stem resulting in a slow release of hydrogen from one tube on the trailer. All tube valves and manifold valves were closed. As a precaution, emergency crews evacuated the immediate area. A team from the trailer company was dispatched to the scene. Before up-righting the trailer, they vented the remaining hydrogen through the vent stack and purged the tubes with nitrogen. There was no fire.

Event Date
February 12, 2008
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

INITIATING CAUSE was a traffic accident. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

Valve stem

Storage/Process Medium
Storage/Process Quantity
188
Actual Pressure
16
Design Pressure
16
Location Type
Operational Condition
Consequences
Number of Injured Persons
1
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

199320

Property Loss (offsite)

0

Post-event Summary

The driver was light injured. 60 to 70 people were evacuated. Material Loss: $4,320. 00 Carrier Damage: $150,000. 00 Property Damage: $0. 00 Response Cost: $15,000. 00 Remediation/Cleanup Cost: $30,000. 00

Lessons Learned

Road incidents, such as crash and loss of control of vehicles during driving are unavoidable initiating causes. The transport company believed difficult to identify additional improvements to structures and packaging able to face impact forces typical of severe incidents like this one. In this case, the design safety features definitively impeded large and rapid confinement losses, and the break at the valve stem allowed only a slow release which could disperse before formation of a possible flammable mixture. However, there are other similar impacts which brought to higher hydrogen releases and ignition

Event Nature
Emergency Action

As a precaution, emergency crews evacuated the immediate area. A team from the trailer company was dispatched to the scene. Before up-righting the trailer, they vented the remaining hydrogen through the vent stack and purged the tubes with nitrogen. There was no fire.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident E-2008030191 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)

New York time news of 13 February 2008 https://www. nytimes. com/2008/02/13/nyregion/13leak. html (accessed December 2025)