Skip to main content

Explosion (644)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion

A vapour explosion, followed by a fire, occurred at a drier in a plant making titanium sponge. When titanium containing water was put into the drier, it came to contact with the edge of the protecting tube of the inside thermometer, generating sparks which ignited the titanium sponge. The red-hot titanium sponge melted the drier to leak out, and reacted with water spilled from the fractured drier, producing hydrogen gas. This led to the vapour explosion scattering titanium, which ignited the nearby products of titanium.
Event Date
August 14, 1981
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The ROOT CAUSE was a fault of th whole design. Moreover, management of the operations should have realised the intrinsic hazard of the operatios, and intervene.

Facility Information
Application Type
Application
Special metals processing
Specific Application Supply Chain Stage
Components Involved
titanium sponge, dryer,
Location Type
Operational Condition
Consequences
Number of Injured Persons
4
Number of Fatalities
1
Event Nature
Release Type
Release Substance
H2, H2O, titanium
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Orignal source lost. RISCAD is closed.