Accidental production of hydrogen in an manufactory of electronics products
The event occurred at the factory producing multilayer circuit boards by a multistep dip operation. An employee inadvertently mixed 55 gal of 50 percent hydrogen peroxide into 110 gal of 30 percent formaldehyde. This resulted in a carbon monoxide and hydrogen release. The facility was evacuated and the local fire department and ambulance responded. 14 workers, out of whom three were from temporary employment agencies, were treated for inhalation and released. The employee did not look carefully at the label on the hydrogen peroxide drum. Both hydrogen peroxide and formaldehyde are in similar black 55 gal poly drums with labels on one side.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was that staff advertently mixed two chemicals which produced and released of carbon monoxide and hydrogen. The fact that the two products containers were not easily distinguishable hints at a management and/or job factor.