Explosion in a metallurgy plant
Explosion within a blast furnace occurred at the plant manufacturing iron. The event occurred at one of the blast furnace of the plant, which exploded. The explosion was so powerful that the entire furnace, which with its contents weighed approximately 5000 tonnes, raised some 0. 75 m from its supporting structures, leading to the explosive release of hot material: the released substances, 200 tonnes in total, consisted in solids, semi-solids, (molten metal) and gases. The event caused three fatalities, twelve severely injured workers and many more with minor injuries. The explosion occurred after two days in which it had been attempted to recover the furnace from a chilled-hearth situation caused by cooling water ingress. The water leak into the furnace also caused an increase in temperature of the molten metal, and the production of hydrogen and oxygen via thermolysis (dissociation of water by heat). The hydrogen detectors gave an increased concentration levels: instead of the usual signal below 2%, during the previous two days the hydrogen detectors reading could exceed 7%. The released gases were mainly carbon monoxide and hydrogen.
The INITIATING CAUSE of the explosion was water and hot molten materials mixing within the lower part of the furnace vessel. At the origin of this situation was the failure of safety-critical water cooling systems, which cased water entering the furnace. According to the HSE report (see references), the INTERMEDIATE CAUSES were failures in health and safety management. , which were not only confined to the blast furnace plant, but extended elsewhere within the company (in particular to the department supplying cooling water for the furnace). There was insufficient redundancy and security of cooling water supplies, and overall cooling system reliability showed a downward and deteriorating trend over several months. The ROOT CAUSE was the lack of a suitable and sufficient risk assessments for blast furnace operations, having as a consequence the failure to implement robust technical and procedural controls.
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.
Contact info
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.