Explosion in an urea manufactory
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting this gas into the atmosphere it is washed with a carbamate solution. This absorption is carried out in a high pressure scrubber, where the explosion occurred. The internals were damaged without affecting the vessel itself as it was designed to take an explosion. A second explosion occurred in April 1974 and also damaged the internals.
Event Date
February 1, 1974
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The presence of hydrogen traces in the carbon dioxide is unavoidable. Oxygen is injected in the system because the urea reactor is made of steel. Formation of hydrogen-oxygen explosive mixture was caused by a very effective adsorption of the other off-gas components. The ignition source was probably oil traces in the absorption part of the scrubber caused explosion.