HIAD Quality Indicator: 3


A liquid hydrogen tanker was returning empty to its home terminal. When the drivers noted that the inner vessel was building pressure. The drivers advised their supervisor and were advised to find a…
A liquid hydrogen tanker was returning to the base after having deliver data customer site. The tank was empty. Nevertheless, on the road the drivers noticed a continuing elevated pressure. To avoid…
The vessel affected by the incident was a gas storage used for the hydro-desulphurisation process. The desulphurisation gas had high hydrogen content. The vessels had cracks in the upper transverse…
A hydrogen leak occurred at a tube bundle container at the loading and unloading bay of a PSA (Pressure Swing Adsorption) hydrogen production plant. During the hydrogen filling process, a worker in…
The bonnet of a 2-inch valve on a hydrogen quench line of a lube oil hydrotreater began to leak. 12 minutes later ignition occurred with fire engulfing the upper portion of the unit. The operative…

During a gaseous hydrogen trailer filling operation, a burst disc relieved, causing a gas release. The gas flow caused the vent pipe to separate at the flared tube fitting, resulting in a fire.…

Minor leak in the break-away coupling for 35MPa dispenser of a refuelling station for buses. The leak developed in the break-away coupling during a controlled test refuel. The test was attended by…
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a…
A LH2 road transporter experienced a fire on a rear tire. The driver tried unsuccessfully to extinguish the fire out with the on-board fire extinguisher, then he called the 911 and disconnected the…
Approximately 250kg hydrogen gas released from vent stack following failure of a relief valve on bulk hydrogen installation. No ignition and no injuries. The system had been recently installed. It…
A truck loaded with hydrogen gas cylinders bundles (3 bundles of 30 cylinders, 1 bundle of 12 cylinders) was traveling on a seaside road. The nylon rope holding the bundles broke due to excessive…
A CGH2 tube trailer had been filled at the production facility and was parked awaiting pickup by the company. A rupture disc failed on one of the cylinders resulting in the release to the atmosphere…
A leak occurred on a line connecting the hot separator to the cold separator of a refinery diesel desulphurization. The alert was given by the activation of the fixed H2S detector. The 30 bar…
A hydrogen and fuel cells bus experienced a hydrogen detection alarm in a city centre. This triggered the evacuation of the immediate surroundings and the towing of the vehicle to the maintenance…
A truck-trailer carrying compressed hydrogen cylinders stopped on an highway and reported a hydrogen leaking from the cylinders. The highway was immediately closed in both directions. When the fire…
A sudden failure occured on a hydrogen line of a refinery desulphurisation unit. The equipment was located between a hydrogen compressor and its overpressure protection valve. It was equipped with an…
During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few centimetres…
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour…
A truck carrying 6,000 gallons of liquid hydrogen (1,600 kg) experienced an accidental loss of confinement while travelling. The truck driver noticed a white vapour cloud coming from the rear of his…