Pressure increase in a LH2 tanker

A liquid hydrogen tanker was returning empty to its home terminal. When the drivers noted that the inner vessel was building pressure. The drivers advised their supervisor and were advised to find a safe location and to safely vent -off the pressure. The pressure was successfully reduced and the tank stabilised. The trailer could resume the travel. The inspection found that the annular space vacuum had degenerated to 1000 microns, allowing an increased heat transfer which caused the pressure rise. A vacuum integrity check was completed and the vacuum restored before the next loading of the trailer.
Event Date
December 28, 1998
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIAL was an increase of the pressure inside the LH2 trailer. The ROOT CAUSE was a reduction of the thermal isolation capacity of the tank external shell.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
vacuum thermal insulation
Storage/Process Medium
Storage/Process Quantity
3888
Location Type
Operational Condition
Pre-event Summary

The LH2 trailer had a capacity of 3500 kg, but it was almost empty, containing only gaseous hydrogen

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

900

Property Loss (offsite)

0

Post-event Summary

Only 1. 0 kg went lost during the manual ' stabilisation' venting.

Lessons Learned
The safe systems and procedures worked as expected. The increase in pressure was due to a decrease of the thermal isolation capacity of the tank external shell. For these cases, in this type of LH2 trailer-tractor the drivers could continuously monitor the pressure from inside the cabin, and notified the head quarter, receiving instructions. They were trained in performing a procedure called in jargon a ‘ stabilisation’ of the tank pressure, consisting in a manual venting aiming at reducing the pressure well below the nominal value.
Event Nature
Emergency Action
The increase in pressure was handled by performing a manual venting which brought back the pressure to a value lower than the nominal one.