Pressure increase in a LH2 tanker
A liquid hydrogen tanker was returning empty to its home terminal. When the drivers noted that the inner vessel was building pressure. The drivers advised their supervisor and were advised to find a safe location and to safely vent -off the pressure. The pressure was successfully reduced and the tank stabilised. The trailer could resume the travel. The inspection found that the annular space vacuum had degenerated to 1000 microns, allowing an increased heat transfer which caused the pressure rise. A vacuum integrity check was completed and the vacuum restored before the next loading of the trailer.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL was an increase of the pressure inside the LH2 trailer. The ROOT CAUSE was a reduction of the thermal isolation capacity of the tank external shell.