A Bourdon tube ruptured in pressure gauge after 528 hours of operation in LH2. The alarm sounded, the system was isolated and then vented. [Ordin, NASA (1974)]
An LH2 trailer-tractor was traveling on a highway. A second vehicle crossed the centreline striking the left rear tandems of the LH2 trailer. The impact caused the trailer-tractor to lose control…
Driver lost control of vehicle ran off highway on right side into wooded area. The front vessel pressure gauge was knocked off the trailer tank. A small amount of gaseous hydrogen was vented until…
A car crashed into a liquid hydrogen tanker. The piping and the inner and outer shell of the liquid hydrogen tanker were completely destroyed, resulting in a fire. [Zalosh and Short, 1978]
A continuous venting of hydrogen from a LH2 tanker occurred during highway transportation. Trailer delivered at test site and vacuum pressure checked to be less than 1 micron. The tank pressure…
[Note HIAD validator: this an incident where a hydrogen system was affected, as effect of the initiating event, overpressure of LH2 tank with helium, but it is not a LH2 incident]. The second…
During the warm-up phase of a large liquid hydrogen sphere, the annular space was over-pressurised and perlite insulation was expelled through the evacuation nozzle and the burst diaphragm. Air…
After a test of a LH2 vessel, during the warm up phase, the plan was to dispose of the hydrogen through the vent system. However, a leak to atmosphere occurred. This was due to a blind flange…
This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…
During initial resting at a liquid hydrogen bubble chamber facility, an explosion occurred shortly after opening a high pressure hydroger line. The explosion was assumed to have taken place in the…
The incident occurred at end of a hydrogen fuel pump test, when large volume of gaseous hydrogen was vented off. An explosion occurred at or near the top of the vent stack, with damage to stack…
A large quantity of hydrogen was being vented to atmosphere during pre-chill operations. Normal pre-cooling time was about 45 minutes, but due to technical problems, the pre-cooling continued for…
The event occurred during the testing of a LH2 pump. When the air turbine pump drive was initiated, the cool down of pump loop was underway, and the speed had increased to design condition and…
During operation of a gaseous hydrogen purifier system, an explosion occurred when the valves were actuated to admit hydrogen. The purifier consisted of a precooler coil immersed in liquid…
An explosion occurred in a Dewar used for metals tensile testing at liquefied hydrogen temperatures. The container consisted of vacuum insulated bottom and of cylindrical shaped polyurethane foam…
This event occurred at after the testing of a LH2 tank. The LH2 was then removed and the tank purged with helium gas for more than 4 hours. A flange was then removed to allow for insertion of…