Hydrogen leaked from a liquid hydrogen tank-trailer parked at a rest area of a highway. The release was remarked as a plume of with vapour, plausibly caused by cold hydrogen release and vapour…
A leak occurred near the bottom of a stationary liquid hydrogen tank with a capacity of a 6,000-gallon. The leak was localised on a valve and was visible due to the air condensation forming white…
In 1990 the Space Shuttle fleet was grounded for several months by an elusive hydrogen leak occurring during the procedure of fuelling of the liquid hydrogen tank of a space shuttle. The Columbia…
The event occurred during a pressure testing of a LH2 pump discharge system. A weld joint failed at an internally tied bellows. The weld failed at 1100 psi (ca. 76 bar) while the test pressure…
A liquid hydrogen leak occurred at the aerospace company (high Tier Seveso). The facility is specialised in production and handling of cryogenic propellants for engines of space vehicles. A 53 m³…
During transfer of LH2 from a 200,000 gallon (760 m3) storage vessel to a road trailer, loss of vacuum was detected due to a crack in the outer vessel. The crack was located below an elbow of the…
A liquid hydrogen tanker was traveling west bound on a highway, when adverse weather conditions (snow and wind) caused a brief "whiteout". To avoid a group of vehicles stopped in front…
A liquid hydrogen tanker was travelling on a highway, when it overturned. The product remained secure within the trailer and there was release to atmosphere during the accident. During the clean…
A LH2 hydrogen went off road and overturned. There was no spillage. All regulatory agencies were notified and the road was closed for an extended period of time.
A liquid hydrogen tanker (with a water capacity of 2000 l) was passing a highway interchange, when the safety valve of the tank activated, releasing hydrogen gas. The drivers stopped first on the…
A liquid hydrogen tank tanker detached from the tractor due to equipment failure. The liquid hydrogen was tansferred to another tanker. During this operation a release of 58,000 cu ft occurred.…
This near miss affected a testing installation for liquid hydrogen. A leak was located on a valve installed on a purge line connected with a LH2 storage tank. This shut-off valve served to…
A rupture disc opened on a 76 m3 (20,000-gallon) liquid hydrogen tank, causing the vent stack to release cold gaseous hydrogen. The gas ignited causing a fire on the vent stack's outlet.…
According to local news, a "hydrogen tanker truck hauling was on fire" at a travel centre on a highway. The videos show, however, simply a flame from what probably is the pressure relief…
While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the…