Skip to main content

Liquid hydrogen release from a tanker (1011)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Liquid hydrogen release from a tanker

The tanker truck was carrying nearly 13,000 gallons of liquid hydrogen (3480 kg). While turning around in the parking place of a local grocery store, the driver hit the base of a light pole. The vent valve of the LH2 tank was severed and started leaking liquid hydrogen. One of the source reported that the leaking hydrogen created an evaporting pool on the ground witha diamter of 19. 2 yards (17. 6 m). Experts from both the U. S. and Canada arrived to investigate the accident. They evacuated all local businesses and roads leading to the grocery store parking lot. Officials were able to off-load the liquid hydrogen from the damaged tanker truck to another tanker and remove it from the area. Nobody was physically harmed by the incident. The intervention lasted approximately 20 hours. One source reported a loss of only 2000 gallon of hydrogen (540 kg), corresponding to approximately 15% of the total content. Another source reported a loss of 1470 kg, corresponding to 42% of the content. The latter source (See refrence, Luo e al. ) reprot also that the spill lasted 4 minutes, with a max leak rate of 2190 pounds/minute (990 kg/minute).
Event Date
October 23, 2017
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
INITIAL and ROOT CAUSE: a mistake in manoeuvring
Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
vent line
Storage/Process Medium
Storage/Process Quantity
3486
Storage/Process Units
Actual Pressure
1
Design Pressure
1
Location Type
Location description
DESCRIPTION OF THE UNIT The tank was 40 feet long with adiameter of 8 feet. Tank Volume 15,040 gallons The quantity of hydrogen carried corresponded to 86% of the maximal tansport capacity of 4030 kg.
Operational Condition
Pre-event Summary
The accident occurred when the driver was turning in a parking place.
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

242924

Property Loss (offsite)

0

Post-event Summary

no explosions, no injuries, and no damage to any nearby houses or businesses. One source reported a loss of only 2000 gallon of hydrogen (540 kg), corresponding to approximately 15% of the total content. Another source reported a loss of 3234 punds (1470 kg), corresponding to 42% of the content.

Lessons Learned
After the crash into the pole, local officials on hand realised the danger because the truck was properly labelled with a UN1966 placard. Therefore, officials were able to respond quickly and evacuated all local businesses and roads leading to the grocery store parking lot where the accident took place. Officials went door to door to local residents recommending that they seek shelter. The main goal was to not only keep everyone in nearby houses and businesses informed of the incident and safe, but to also stop any potential leaking. This conforms the importance of the proper label, made clearly visible on the hazardous materials transporter.
Event Nature
Emergency Action
As experts from both the U. S. and Canada arrived to investigate the accident and help determine the safest way to handle the incident, officials eventually were able to off-load the liquid hydrogen from the damaged tanker truck to another tanker and remove it from the area. The whole incident lasted about 20 hours and resulted in no explosions, no injuries, and no damage to any nearby houses or businesses.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Incident E-2017110428 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)

Online news of the Compliance Center, November 16, 2017: https://www. thecompliancecenter. com/ca/hazmat-incident-in-niagara-falls/ (accessed Dec 2024)

Luo et al, Modelling the consequences of a liquid hydrogen leak using ALOHA software: Case Study of a Liquid Hydrogen (UN1966) Tanker Accident, International Journal of Natural Resources and Environmental Studies, 3 (2024), https://doi. org/10. 62051/ijnres. v3n1. 16