Damage of shipping containers of a ship, due to the reaction of phosphor pentoxide with wine, which lead to the production of phosphoric acid and hydrogen. The overpressure was successfully…
An explosion and a fire occurred at at a hydro-treatment unit of a chemical plant for lubricants. Plant own emergency response team was activated, assisted from local fire and emergency Services and…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
A contained explosion in a hydrogen tank occurred at the thermal generation plant
The event occurred in the hydrogen pumping station, placed between the hydrogen production unit (steam methane reformer) and the hydro-treatment unit. The second stage of the compressor cylinder…
A welder was welding a stainless steel drain pipe with an arc welder, above a sulphuric acid storage tank. When he lowered the pipe, the hydrogen gas in tank ignited causing an explosion and one…
A hydrogen production plant was affected by an exploded, throwing debris for tens of metres and badly damaging the plant. The two workers in the plant at the time were not seriously injured. The…
The incident occurred on two hydrogen compressor units installed on the roof of a four-story building. The Great East Japan Earthquake caused the rupture of the flexible piping and the outlet piping…
A jet fire occurred on the ammonia production unit, caused by a leak on a hydrogen pipe. Hearing a strange noise, an employee triggered the alarm after having discovered an ignited jet of hydrogen.…
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
A severe fire in a hydrogen compressor building in a an oil sands refinery reportedly started in a 1,500 psi (103 bar) lube oil system. Fire fighting was difficult because of 40 degrees F temperature…
The incident occurred outside a fuel cells manufacturing facility. While preparing for transfer of liquid hydrogen from tanker truck to a stationary storage tank, a release of hydrogen occurred,…
A hydrogen tank exploded and caught fire at a chemical plant.
The tanker truck was carrying nearly 13,000 gallons of liquid hydrogen (3480 kg). While turning around in the parking place of a local grocery store, the driver hit the base of a light pole. The vent…
A liquid hydrogen tanker had just departed from the home terminal, when the driver notice vapours coming from the curb side of the trailer control cabinet. The driver stopped the vehicle at the…
The bonnet of a 2-inch valve on a hydrogen quench line of a lube oil hydrotreater began to leak. 12 minutes later ignition occurred with fire engulfing the upper portion of the unit. The operative…
a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.
Leaking hydrogen ignited at a plant that processes bitumen from oil sands.
The incident occurred at the steam methane reformer unit producing hydrogen. The event occurred just after that start-up steam was introduced into the reformer furnace inlet. At this moment a very…