Steam reformer explosion at a oil production plant
The incident occurred at the steam methane reformer unit producing hydrogen. The event occurred just after that start-up steam was introduced into the reformer furnace inlet. At this moment a very high pressure and a single loud bang was reported by the operations personnel on the furnace structure. The investigation concluded that the mechanical failure of the reformer was due to flash evaporation of water still in liquid form, which caused an abnormal pressure peak. This is therefore an accident involving a hydrogen system, but where hydrogen did not have a role in the accidental sequence. Since the incident occurred at the re-start of the reformer, probably the hydrogen quantities were negligible An emergency shutdown of the furnace was initiated and the start up aborted. At the time of the incident there were 7 people on the furnace. Four were operations staff plus three maintenance personnel.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was accidental injection of remnant water into the furnace. The ROOT CAUSE was related to organisation aspects such as inappropriate safety design risk, (see lesson learned)