Skip to main content

Over-pressurisation of a LH2 tanker (547)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Over-pressurisation of a LH2 tanker

A liquid hydrogen tanker had just departed from the home terminal, when the driver notice vapours coming from the curb side of the trailer control cabinet. The driver stopped the vehicle at the closest weight station and discovered that the vapours were coming from the body of the pressure relief valve. A response team from the home terminal discovered that the plug in the body of the relief valve was missing. The relief valve was isolated from the system and the trailer was safely returned to the home terminal, where the missing plug was replaced. The trailer was tested for leaks and released for the next scheduled trip (11 hr).
Event Date
February 9, 1998
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIAL CAUSE of the leak was a defective valve (the body of the valve was missing). The ROOT CAUSE seems to be thean error in the valve installation/maintenance.
Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
PRV
Storage/Process Medium
Storage/Process Quantity
3524
Location Type
Operational Condition
Pre-event Summary
The LH2 tanker had just departed full from the home terminal
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

300

Property Loss (offsite)

0

Post-event Summary

A negligible amount of hydrogen was released.

Event Nature
Emergency Action
The driver stopped the vehicle at the closest weight station. A response team from the home terminal intervened, isolated the relief valve and the tanker was safely returned to the home terminal, where the missing plug was replaced.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Incident I-1998020791 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)