Liquid spilling from a LH2 tanker (73)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Liquid spilling from a LH2 tanker

While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the rear cabinet doors, the driver noticed the liquid hydrogen was leaking by the fire control and manual valve for the fill and withdrawal valve. The product was slowly dripping down onto the cabinet floor and vaporising. The driver could see no visible cause for the product passing through the valves as they were tight. There was no other choice than safely venting the product to the atmosphere. The tanker returned to the home terminal for evaluation. It was found that the fire control valve failed to close completely due to a piece of ice partially blocking the valve seat. Once that the ice was removed, the valve worked properly. The tanker was returned to service.

Event Date
February 5, 1992
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE of the liquid hydrogen spilling was the block of a valve in partially open position due to ice formation. The ROOT CAUSE was probably related to the failing to perform properly the procedure at the moment of the filling of the tanker.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

valve

Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

170

Property Loss (offsite)

0

Post-event Summary

The source report only a partial loss of the hydrogen content.

Event Nature
Emergency Action

The driver vented safely the hydrogen to the atmosphere.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event incident ID I-1992020141 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996), https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages (accessed September 2024)