LH2 valve leaking at a research centre
This near miss affected a testing installation for liquid hydrogen. A leak was located on a valve installed on a purge line connected with a LH2 storage tank. This shut-off valve served to discharge hydrogen into the exhaust stack of the installation, in case LH2 evaporation from the filling or withdrawal hose was causing excessive pressure. It was also serving a purging purpose, by flushing the filling hose with gaseous hydrogen before filling the cylinder with LH2. The valve was more than 20 years and was not sealing properly under cryogenic conditions, causing hydrogen gas to escape from the threated connection between the valve stem and the valve case. The valve failed on two internal parts: the metal diaphragm and the O-ring that served as a seal (a sealing with thoric geometry). The metal diaphragm no longer seated properly against the valve seat causing leakage.