Skip to main content

Liquid hydrogen release from a truck (943)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Liquid hydrogen release from a truck

The leak occurred on a 44 m³ vehicle of liquid hydrogen during a delivery to the unloading station of a steel plant. The truck drivers had connected the tank container to the fixed storage managed by a subcontractor, carried out a nitrogen sweep of the hose before cooling it, and were pressurizing the hydrogen before unloading when they saw a white cloud. The drivers closed the bottom valve of the container and the upstream and downstream valves of the heater before evacuating the area and sounding the alarm. Two technicians of the subcontractor company arrived 30 minutes later, located the leak on the flange of one of the four protective valves of the tank container. Two of the four fixing bolts were missing from the leaking flange. The technicians closed the three ways valve which allowed to isolate the valves 2 by 2. They could then re-seale the flange correctly and performe a leak test.
Event Date
September 20, 2011
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the lack of tightness of a cryogenic tank flange, which started releasing when raising the pressure,. The root cause was inadequate reassembling of some of the flange bolts during the previous maintenance, performed 17 days before.
Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
liquid hydrogen cryogenic tank, truck, liquid hydrogen heater
Storage/Process Medium
Storage/Process Quantity
3200
Actual Pressure
1
Design Pressure
1
Location Type
Location description
DESCRIPTION OF THE PROCESS This process consisted in: 1) connecting the tank container to the fixed storage 2) execute a nitrogen sweep of the hose and cooling it, 3) pressurizing the H2 before unloading. The tank had a volume of 44 m3 corresponding to approximately 3200 kg of liquid hydrogen at full load. The customer was a steel manufacturer.
Operational Condition
Pre-event Summary
The tank drivers had started the procedure for unloading and evaporating the liquid hydrogen.
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

F

Lessons Learned
The ARIA report (see references) does not mention any corrective action, and also the real cause of the lack of tightness of the leaking flange is not identified. There could be three non-exclusive root causes: (1) Rad vibration which could loosen the bold. (2) a human cause, because the maintenance procedure or the checks before tank delivery were not followed. (3) an inadequate procedure, which (for example) does not foresees even a leak test under pressure after the maintenance, and/or a confinement integrity check before starting the hydrogen transfer . In the first case, personnel training is required, in the second, a review of the procedure is required, probably assessed by a new risk assessment.
Event Nature
Emergency Action
The public rescue services established a 150 m safety perimeter and evacuate 50 employees. The road traffic was interrupted for less than one hour. After the end of the emergency status, the operation of unloading the hydrogen was restarted and successfully brought to an end.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description in the French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/40965/ (accessed October 2020)

News of the event in Ouest France, 20/09/2011 https://nantes. maville. com/actu/actudet_-une-fuite-d-hydrogene-vite-maitrisee-sur-le-site-d-arcelormittal-a-indre-ce-matin_39904-1995708_actu. Htm (accessed October 2020)