Continuous release from a LH2 tanker
A continuous venting of hydrogen from a LH2 tanker occurred during highway transportation. Trailer delivered at test site and vacuum pressure checked to be less than 1 micron. The tank pressure was 50 psig (ca. 3. 5 bar). Attempts were made to stop the venting by thawing the manual vent valve; also, the burst disc was nearly frosted. eventually, the LH2 was transferred and the external piping warmed with water. The rupture disc was replaced. The loss was about 3886 gallons (ca 14710 l = ca. 1 t of hydrogen). [Ordin, NASA (1974)]
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

3. The rupture disc had a number of holes but was not completely blown out. The leak probably existed throughout the entire trip.