Skip to main content

Continuous release from a LH2 tanker (355)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Continuous release from a LH2 tanker

A continuous venting of hydrogen from a LH2 tanker occurred during highway transportation. Trailer delivered at test site and vacuum pressure checked to be less than 1 micron. The tank pressure was 50 psig (ca. 3. 5 bar). Attempts were made to stop the venting by thawing the manual vent valve; also, the burst disc was nearly frosted. eventually, the LH2 was transferred and the external piping warmed with water. The rupture disc was replaced. The loss was about 3886 gallons (ca 14710 l = ca. 1 t of hydrogen). [Ordin, NASA (1974)]

Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

3. The rupture disc had a number of holes but was not completely blown out. The leak probably existed throughout the entire trip.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

burst disc

Storage/Process Medium
Actual Pressure
0
Design Pressure
0
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

15000

Post-event Summary

A loss of 1000 kg of hydrogen. Assuming a cost of hydrogen of 12 to 15 US$, an order of magnitude of the propoerty total loss could be estimated.

Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Mishap no 3 in P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565 https://ntrs. nasa. gov/citations/19740020344